Melentiev Vladimir Sergeevich, doctor of technical sciences, professor, head of sub-department of information
and measuring equipment, Samara State Technical University, vs_mel@mail.ru
Ivanov Yuriy Mikhaylovich, candidate of technical sciences, senior researcher, sub-department of information
and measuring equipment, Samara State Technical University, fuego@rambler.ru
Muratova Vera Vladimirovna, graduate student, Samara State Technical University, muratova1991@yandex.ru

Index UDK

 621.317

Abstract

The new method of measurement of the integrated characteristics, based on formation of two additional voltage signals and definition of instant values of an entrance voltage and a current at the moment of transition of additional signals through a zero is considered. Results of the analysis of an error of parameters measurement because of a deviation of real signals from harmonious model are examined.

Key words

integrated characteristics, harmonious model, instant values, the additional signals, the phase-shifting block, error.